Model(s): NMG 115, NMG 130, NMG 163, NMG 1126, NMG 1317
*Scroll to the right on mobile to see entire chart
Model |
Inlet Air Pressure (psig) |
Rated Outlet Flow |
nitrogen purity at the outlet (max oxygen content) |
99.9% (0.1%) |
99.5% (0.5%) |
99% (1%) |
98% (2%) |
97% (3%) |
96% (4%) |
95% (5%) |
NMG 115 |
100 |
scfh |
8 |
15 |
23 |
29 |
38 |
49 |
56 |
125 |
scfh |
12 |
21 |
32 |
42 |
56 |
67 |
77 |
150 |
scfh |
13 |
24 |
35 |
45 |
63 |
77 |
91 |
200 |
scfh |
20 |
35 |
56 |
70 |
95 |
113 |
134 |
NMG 130 |
100 |
scfh |
16 |
30 |
46 |
58 |
76 |
98 |
112 |
125 |
scfh |
24 |
42 |
64 |
84 |
112 |
134 |
154 |
150 |
scfh |
26 |
48 |
70 |
90 |
126 |
154 |
182 |
200 |
scfh |
40 |
70 |
112 |
140 |
190 |
226 |
268 |
NMG 163 |
100 |
scfh |
32 |
63 |
84 |
130 |
165 |
204 |
243 |
125 |
scfh |
44 |
87 |
116 |
176 |
226 |
278 |
328 |
150 |
scfh |
50 |
101 |
134 |
197 |
257 |
314 |
388 |
200 |
scfh |
73 |
146 |
194 |
293 |
388 |
459 |
529 |
NMG 1126 |
100 |
scfh |
63 |
126 |
168 |
260 |
330 |
408 |
486 |
125 |
scfh |
87 |
174 |
232 |
352 |
452 |
556 |
656 |
150 |
scfh |
100 |
200 |
268 |
394 |
514 |
628 |
776 |
200 |
scfh |
145 |
290 |
388 |
586 |
776 |
918 |
1058 |
NMG 1317 |
100 |
scfh |
159 |
317 |
423 |
600 |
777 |
953 |
1130 |
125 |
scfh |
212 |
423 |
565 |
812 |
1059 |
1306 |
1518 |
150 |
scfh |
238 |
476 |
635 |
918 |
1200 |
1447 |
1730 |
200 |
scfh |
393 |
714 |
953 |
1341 |
1765 |
2154 |
2500 |
*Scroll to the right on mobile to see entire chart
Specifications |
Inlet & outlet connections |
½" NPT |
Design operating pressure range |
100 to 200 psig |
Design operating temperature range |
41 to 113°F |
Pressure drop |
7 to 10 psig |
➤Click Here for Inlet Air to Outlet Nitrogen Ratio
Options
• System Standby / Hibernation
○ Includes pressure switch & inlet air solenoid valve. Allows system standby when demand is limited (requires 115/1/60 power supply)
Fits All models Suffix: SS
• Outlet Purity Control
○ Outlet Purity Control includes needle valve with inline flow meter
Fits All models Suffix: OPC
• NMG output analyzer
○ 0-25% range, dry alarm contacts, 4-20mA output
Fits All models Suffix: OA
• NMG filter elements & drain service kits
○ Replacement filter elements & drain service kits
Fits Separator/filter: NF 0070 M1 | Replacement filter element1: E 0090 M1 | Drain Service Kits2: NDK 1500
Fits Separator/filter: NF 0070 M01 | Replacement filter element1: E 0090 M01 | Drain Service Kits2: NDK 1500
Fits Separator/filter: NF 0070 AC | Replacement filter element1: E 0090 AC3 | Drain Service Kits2: n/a
(1) for easy identification, elements are color coded. Ensure new element is the same color as the element being replaced. For element specifications and colors refer to “specifications”
(2) NMD MK6 is a drain service kit. NDK 1500 is a complete replacement drain
*Scroll to the right on mobile to see entire chart
Model |
A (in) |
B (in) |
C (in) |
Weight (lbs) |
NMG 115 |
26" |
29" |
12" |
25 |
NMG 130 |
26" |
29" |
12" |
30 |
NMG 163 |
40" |
48" |
12" |
40 |
NMG 1126 |
40" |
48" |
12" |
51 |
NMG 1317 |
34" |
53" |
12" |
69 |