Model(s): NVR 0185, NVR 0370, NVR 0750, NVR 1100, NVR 1500
*Scroll to the right on mobile to see entire chart
Model |
Service Kit |
Inlet & Outlet NPT |
Rated Flow1 |
Qty |
Part No. |
Scfm |
Nm3/h |
NVR 0185 |
1 |
NVR SK 185 |
1" |
185 |
315 |
NVR 0370 |
1 |
NVR SK 370 |
1" |
370 |
630 |
NVR 0750 |
2 |
NVR SK 370 |
2" |
750 |
1275 |
NVR 1100 |
3 |
NVR SK 370 |
2" |
1100 |
1870 |
NVR 1500 |
4 |
NVR SK 370 |
2½" |
1500 |
2550 |
(1) at inlet conditions of 100 psig and 95°F, and 95°F ambient temperature. For all other operating
conditions refer to the correction factors
(2) includes purification cartridges (including integral inlet diffusers and outlet particulate filters)
and all o-rings
*Scroll to the right on mobile to see entire chart
Specifications |
maximum working pressure |
232 psig |
recommended operating temp range |
36 to 95°F |
maximum operating temperature |
122°F |
estimated cartridge life |
6000 hrs3 |
(3) provided as an estimate only. Cartridges must be replaced as required to maintain adequate air
quality in accordance with all applicable codes and regulations.
*Scroll to the right on mobile to see entire chart
inlet air quality requirements4 |
maximum particulate size |
0.01 micron |
maximum presure dew point |
-40°F |
maximum oil content |
0.05 mg/m3 |
performance |
maximum outlet air oil content (@95°F) |
0.003 mg/m3(ppm) |
(4) if the air doesn’t meet these conditions, contact mdi to confirm the additional
treatment required
➤Click Here for Correction Factors
There are no options available at this time.
*Scroll to the right on mobile to see entire chart
Model |
A (in) |
B (in) |
C (in) |
Weight (lbs) |
NVR 0185 |
17.3" |
9.7" |
25.4" |
88 |
NVR 0370 |
17.3" |
9.7" |
31.5" |
110 |
NVR 0750 |
15.8" |
22.6" |
34.3" |
227 |
NVR 1100 |
15.8" |
29.2" |
34.3" |
313 |
NVR 1500 |
15.8" |
35.8" |
34.3" |
397 |