Model(s): GEN2 1110-PLUS, GEN2 2110-PLUS, GEN2 3110-PLUS, GEN2 2130-PLUS, GEN2 3130-PLUS, GEN2 4130-PLUS, GEN2 6130-PLUS, GEN2 8130-PLUS, GEN2 10130-PLUS, GEN2 12130-PLUS
*Scroll to the right on mobile to see entire chart
Model |
Rated Outlet Flow1 |
nitrogen purity at the outlet (max oxygen content) |
99.999% (10 ppm) |
99.995% (50 ppm) |
99.99% (100 ppm) |
99.975% (250 ppm) |
99.95% (500 ppm) |
99.9% (0.10%) |
99.5% (0.50%) |
99% (1%) |
GEN2 1110-PLUS |
scfh |
28 |
54 |
65 |
85 |
102 |
117 |
170 |
201 |
GEN2 2110-PLUS |
scfh |
55 |
108 |
129 |
171 |
204 |
233 |
339 |
403 |
GEN2 3110-PLUS |
scfh |
83 |
162 |
194 |
256 |
307 |
350 |
509 |
604 |
GEN2 2130-PLUS |
scfh |
158 |
224 |
261 |
310 |
354 |
410 |
587 |
653 |
GEN2 3130-PLUS |
scfh |
238 |
336 |
392 |
466 |
531 |
615 |
881 |
979 |
GEN2 4130-PLUS |
scfh |
317 |
448 |
522 |
621 |
709 |
820 |
1175 |
1305 |
GEN2 6130-PLUS |
scfh |
475 |
671 |
783 |
931 |
1063 |
1231 |
1762 |
1958 |
GEN2 8130-PLUS |
scfh |
634 |
895 |
1044 |
1424 |
1417 |
1641 |
2349 |
2610 |
GEN2 10130-PLUS |
scfh |
729 |
1029 |
1201 |
1428 |
1630 |
1887 |
2702 |
3002 |
GEN2 12130-PLUS |
scfh |
846 |
1195 |
1394 |
1658 |
1892 |
2191 |
3136 |
3485 |
(1) at 100 psig inlet pressure and 68 - 77°F inlet temperature. For outlet flow at all other conditions refer to the correction factors or contact sales@mdisales.com
*Scroll to the right on mobile to see entire chart
Specifications |
Standard |
Optional |
design operating pressure range |
87 to 174 psig |
232 psig (consult mdi)2 |
design operating temperature range |
41 to 122°F |
- |
maximum inlet particulate |
0.1 micron |
- |
maximum inlet dew point |
80°F PDP |
- |
maximum inlet oil content |
0.01 ppm3 |
- |
maximum outlet dew point |
-40°F PDP4 |
- |
supply voltage |
100 - 240 VAC (50 or 60Hz) or 24VDC |
- |
(2) 232 psig available as option.
(3) including oil vapor
(4) requires an upstream dryer. Contact mdi for assistance selecting the optimum dryer for your application
➤Click Here for Pressure & Temperature Correction Factors
Options
• High Pressure
○ high pressure (232 psig)
Fits GEN2 3130-PLUS - GEN2 12130-PLUS Suffix: HP
• System Standby / Hibernation
○ includes pressure switch & inlet air solenoid valve. Allows system standby when demand is limited (requires 115/1/60 power supply)
Fits All models Suffix: SS
• Outlet Purity Control
○ Outlet Purity Control includes needles valve with inline flow meter1
Fits all models Suffix: OPC
(1) for easy identification, elements are color coded. Ensure new element is the same color as the element being replaced. For element specifications and colors refer to “specifications”
*Scroll to the right on mobile to see entire chart
Model |
A (in) |
B (in) |
C (in) |
Weight (lbs) |
GEN2 1110-PLUS |
47.8" |
15.7" |
23.0" |
375 |
GEN2 2110-PLUS |
47.8" |
15.7" |
29.6" |
437 |
GEN2 3110-PLUS |
47.8" |
15.7" |
36.2" |
560 |
GEN2 2130-PLUS |
71.3" |
15.7" |
29.6" |
589 |
GEN2 3130-PLUS |
71.3" |
15.7" |
36.2" |
780 |
GEN2 4130-PLUS |
71.3" |
15.7" |
42.8" |
972 |
GEN2 6130-PLUS |
71.3" |
15.7" |
55.9" |
1356 |
GEN2 8130-PLUS |
71.3" |
15.7" |
69.3" |
1739 |
GEN2 10130-PLUS |
71.3" |
15.7" |
82.5" |
2123 |
GEN2 12130-PLUS |
71.3" |
15.7" |
95.6" |
2507 |