Model(s): GEN2 1110, GEN2 2110, GEN2 3110, GEN2 2130, GEN2 3130, GEN2 4130, GEN2 6130, GEN2 8130, GEN2 10130, GEN2 12130
*Scroll to the right on mobile to see entire chart
Model |
Rated Outlet Flow1 |
nitrogen purity at the outlet (max oxygen content) |
98% (2%) |
97% (3%) |
96% (4%) |
95% (5%) |
GEN2 1110 |
scfh |
258 |
293 |
335 |
364 |
GEN2 2110 |
scfh |
516 |
586 |
671 |
727 |
GEN2 3110 |
scfh |
773 |
879 |
1006 |
1091 |
GEN2 2130 |
scfh |
932 |
1070 |
1218 |
1324 |
GEN2 3130 |
scfh |
1398 |
1605 |
1828 |
1986 |
GEN2 4130 |
scfh |
1865 |
2140 |
2437 |
2649 |
GEN2 6130 |
scfh |
2797 |
3210 |
3655 |
3973 |
GEN2 8130 |
scfh |
3729 |
4280 |
4873 |
5297 |
GEN2 10130 |
scfh |
4289 |
4922 |
5604 |
6092 |
GEN2 12130 |
scfh |
4979 |
5714 |
6506 |
7072 |
(1) at 100 psig inlet pressure and 68 - 77°F inlet temperature. For outlet flow at all other conditions refer to the correction factors above or contact sales@mdisales.com
*Scroll to the right on mobile to see entire chart
Specifications |
Standard |
Optional |
design operating pressure range |
87 to 174 psig |
232 psig (consult mdi)2 |
design operating temperature range |
41 to 122°F |
- |
maximum inlet particulate |
0.1 micron |
- |
maximum inlet dew point |
80°F PDP |
- |
maximum inlet oil content |
0.01 ppm3 |
- |
maximum outlet dew point |
-40°F PDP4 |
- |
supply voltage |
100 - 240 VAC (50 or 60Hz) or 24VDC |
- |
(2) 232 psig available as option.
(3) including oil vapor
(4) requires an upstream dryer. Contact mdi for assistance selecting the optimum dryer for your application
➤Click Here for Pressure & Temperature Correction Factors
Options
• Service Kits
○ replacement external silencer (x1) for NPT models
Fits GEN2 1110 - GEN2 3110 Part no.: A-NPT-110
○ replacement external silencers (x2) for NPT models
Fits GEN2 2130 - GEN2 12130 Part no.: A-NPT-130
○ replacement high pressure exhaust silencer (x1) for NPT models
Fits GEN2 2130 - GEN2 12130 Part no.: A-NPT-130HP
○ replacement oxygen sensor solenoid valve
Fits GEN2 1110 - GEN2 1210 Part no.: B-SSVK-130
○ replacement piston valve seals
Fits GEN2 1110 - GEN2 12130 Part no.: C-PVSK-130
○ replacement pilot and control valves
Fits GEN2 1110 - GEN2 12130 Part no.: D-CVK-130
○ replacement Galvanic % cell
Fits GEN2 1110 - GEN2 12130 Part no.: E-GCR-%
○ replacement Galvanic PPM cell
Fits GEN2 1110 - GEN2 12130 Part no.: E-GCR-PPM
○ replacement Zirconia % cell
Fits GEN2 1110 - GEN2 12130 Part no.: F-ZCR-%
○ replacement Zironcia PPM cell
Fits GEN2 1110 - GEN2 12130 Part no.: F-ZCR-PPM
• High Pressure
○ high pressure (232 psig)
Fits GEN2 1110 - GEN2 12130 Suffix: HP
• System Standby / Hibernation
○ includes pressure switch & inlet air solenoid valve. Allows system standby when demand is limited (requires 115/1/60 power supply)
Fits All models Suffix: SS
• Outlet Purity Control
○ Outlet Purity Control includes needles valve with inline flow meter1
Fits all models Suffix: OPC
(1) for easy identification, elements are color coded. Ensure new element is the same color as the element being replaced. For element specifications and colors refer to “specifications”
*Scroll to the right on mobile to see entire chart
Model |
A (in) |
B (in) |
C (in) |
Weight (lbs) |
GEN2 1110 |
47.8" |
15.7" |
23.0" |
375 |
GEN2 2110 |
47.8" |
15.7" |
29.6" |
437 |
GEN2 3110 |
47.8" |
15.7" |
36.2" |
560 |
GEN2 2130 |
71.3" |
15.7" |
29.6" |
589 |
GEN2 3130 |
71.3" |
15.7" |
36.2" |
780 |
GEN2 4130 |
71.3" |
15.7" |
42.8" |
972 |
GEN2 6130 |
71.3" |
15.7" |
55.9" |
1356 |
GEN2 8130 |
71.3" |
15.7" |
69.3" |
1739 |
GEN2 10130 |
71.3" |
15.7" |
82.5" |
2123 |
GEN2 12130 |
71.3" |
15.7" |
95.6" |
2507 |