Model(s): DHC8/100, DHC13/100, DHC18/100, DHC26/100, DHC31/100, DHC41/100, DHC52/100, DHC59/100, DHC66/100, DHC8/350, DHC13/350, DHC18/350, DHC26/350, DHC31/350, DHC41/350, DHC52/350, DHC59/350, DHC66/350
*Scroll to the right on mobile to see entire chart
Model |
NPT Inlet & Outlet |
scfm(1) |
Nm3/h(1) |
DHC / 100 (1450 psig) |
DHC8/100 |
½" |
77 |
130 |
DHC13/100 |
½" |
115 |
195 |
DHC18/100 |
½" |
159 |
270 |
DHC26/100 |
½" |
203 |
345 |
DHC31/100 |
½" |
250 |
425 |
DHC41/100 |
¾" |
333 |
565 |
DHC52/100 |
¾" |
394 |
670 |
DHC59/100 |
¾" |
447 |
760 |
DHC66/100 |
¾" |
486 |
825 |
DHC / 350 (5075 psig) |
DHC8/350 |
½" |
132 |
225 |
DHC13/350 |
½" |
206 |
350 |
DHC18/350 |
½" |
283 |
480 |
DHC26/350 |
½" |
365 |
620 |
DHC31/350 |
½" |
441 |
750 |
DHC41/350 |
¾" |
647 |
1,100 |
DHC52/350 |
¾" |
765 |
1,300 |
DHC59/350 |
¾" |
868 |
1,475 |
DHC66/350 |
¾" |
942 |
1,600 |
(1) at an inlet temperature of 95°F, an inlet pressure of 1450 or 5075 psig (as applicable), and a -40°F outlet dew point. For all other operating conditions contact sales@airceldryersales.com for sizing assistance
(2) per ISO 8573.1:2010
*Scroll to the right on mobile to see entire chart
Specifications |
DHC / 100 |
DHC / 350 |
Minimum operating pressure |
435 psig |
435 psig |
Maximum operating pressure |
1450 psig |
5075 psig |
Maximum particle size (ISO class) (2) |
class 2 (1 micron) |
Maximum water content (ISO class) (2) |
class 2 (-40°F pdp) (3) |
Maximum oil content (ISO class) (2) |
class 1 ( 0.01 mg/m3) |
Recommended operating temp range |
50 to 100°F |
Design operating temperature range |
35 to 140°F |
Power supply requirements |
120 & 240 VAC, 50/60 Hz (4) |
Power consumption |
< 50 W |
Control panel protection |
IP 65 (NEMA 4X) |
Valve switching power (per valve) |
80 VA |
(3) ISO class 2 (-40°F outlet pressure dew point) is provided as standard. -13°F or -67°F outlet pressure dew points are available as an option
(4) 24VDC available as an option
➤Click Here for Materials of Construction Chart
options & upgrades
• Dew point monitors
○ integral energy saving outlet dew point control & display
• Low dew point option
○ -67°F outlet pressure dew point (2)
• Bypass option
○ three (3) valve block & bypass
• Electrical protection upgrades
○ NEMA 7 electrical protection
○ Z-Purge electrical protection
• Other options & upgrades
○ low ambient (< 32°F) temperature protection
○ pneumatic controls
○ 220 Volt 1 phase 50Hz controls
○ stainless steel control tubing
○ visual moisture indicator
○ failure to shift alarm
○ run time hour meter
○ additional pressure gauges (each)
○ additional temperature gauges (each)
○ CSA approval for Canadian applications
(2) reduces rated flow by 30%
*Scroll to the right on mobile to see entire chart
Model |
A Height (in) |
B Width (in) |
C Depth (in) |
Weight (lbs) |
DHC / 100 (1450 psig) |
DHC8/100 |
42.3" |
31.0" |
13.4" |
384 |
DHC13/100 |
48.2" |
31.0" |
13.4" |
414 |
DHC18/100 |
54.1" |
31.0" |
13.4" |
441 |
DHC26/100 |
60.0" |
31.0" |
13.4" |
472 |
DHC31/100 |
69.9" |
31.0" |
13.4" |
520 |
DHC41/100 |
67.9" |
32.5" |
13.4" |
666 |
DHC52/100 |
75.8" |
32.5" |
13.4" |
717 |
DHC59/100 |
83.7" |
32.5" |
13.4" |
776 |
DHC66/100 |
93.5" |
32.5" |
13.4" |
631 |
DHC / 350 (5075 psig) |
DHC8/350 |
42.3" |
31.0" |
13.4" |
485 |
DHC13/350 |
48.2" |
31.0" |
13.4" |
545 |
DHC18/350 |
54.1" |
31.0" |
13.4" |
604 |
DHC26/50 |
60.0" |
31.0" |
13.4" |
661 |
DHC31/350 |
69.9" |
31.0" |
13.4" |
758 |
DHC41/50 |
67.9" |
32.5" |
13.4" |
908 |
DHC52/350 |
75.8" |
32.5" |
13.4" |
1,005 |
DHC59/350 |
83.7" |
32.5" |
13.4" |
1,100 |
DHC66/350 |
93.5" |
32.5" |
13.4" |
1,228 |