Model(s): BAP 050 CP N, BAP 050 CP H, BAP 050 CP S, BAP 100 CP N, BAP 100 CP H, BAP 100 CP S, BAP 175 CP N, BAP 175 CP H, BAP 175 CP S
*Scroll to the right on mobile to see entire chart
Model |
Quantity of Inlet Connections |
Inlet Connection |
Quantity of Outlet Connections |
Outlet Connection |
Inlet flows5 scfm |
Outlet flows5 scfm |
BAP 050 CP N |
1 |
½" NPT(F) |
4 |
⅜" NPT(F) |
50 |
50 |
BAP 050 CP H |
1 |
½" NPT(F) |
4 |
¼" Hansen1 |
50 |
50 |
BAP 050 CP S |
1 |
½" NPT(F) |
4 |
¼" Schrader1 |
50 |
50 |
BAP 100 CP N |
1 |
¾" NPT(F) |
4 |
⅜" NPT(F) |
100 |
100 |
BAP 100 CP H |
1 |
¾" NPT(F) |
4 |
¼" Hansen1 |
100 |
100 |
BAP 100 CP S |
1 |
¾" NPT(F) |
4 |
¼" Schrader1 |
100 |
100 |
BAP 175 CP N |
1 |
¾" NPT(F) |
6 |
⅜" NPT(F) |
175 |
175 |
BAP 175 CP H |
1 |
¾" NPT(F) |
6 |
¼" Hansen1 |
175 |
175 |
BAP 175 CP S |
1 |
¾" NPT(F) |
6 |
¼" Schrader1 |
175 |
175 |
(1) female style coupling
(3) contact sale@mdisales.com for higher pressures or flows
(5) flow rates based on 100 psig and 86°F inlet temperature
• contact sales@mdisales.com for intrinsically safe, integrated CO & O2 monitoring or any options or equipment not listed
• quick-disconnect fittings for use in compressed breathing air systems shall be selected to prevent accidental connection to other sources of compressed gas.
*Scroll to the right on mobile to see entire chart
Specifications |
BAP Panels |
operating pressure range (for United States) |
15 to 150 psig |
operating pressure range (for Canada) |
15 to 150 psig |
recommended operating temp range |
35 to 86°F |
Options
• Remote Alarms
○ 120 VAC remote alarm - includes conduit box, audible & strobe alarms
Fits All models Part No.: BAP-RA
• Monitors & Control Options
○ CO monitor humidifier kit
Fits All models Part No.: CO-HUMKIT
○ Replacement CO sensor
Fits All models Part No.: CO-91NS
• Calibration kits & Gases
○ US calibration kit - includes 17L cylinders of 20 ppm CO, zero air, regulator, tubing & hard case
Fits All models Part No.: COL Cal KIT20-17L
○ Large US calibration kit - includes 103L cylinders of 20 ppm CO, zero air, regulator, tubing & hard case
Fits All models Part No.: COL Cal KIT20-103L
○ Canadian calibration kit - includes 17L cylinders of 10 ppm CO, zero air, regulator, tubing & hard case
Fits All models Part No.: COL Cal KIT10-17L
○ Large Canadian calibration kit - includes 103L cylinders of 10 ppm CO, zero air, regulator, tubing & hard case
Fits All models Part No.: COL Cal KIT10-103L
○ 17 liter replacement calibration gas - zero air
Fits All models Part No.: BBG-00017
○ 103 liter replacement calibration gas - zero air
Fits All models Part No.: BBG-00103
○ 17 liter replacement calibration gas - 20 ppm CO (USA)
Fits All models Part No.: BBG-20017
○ 103 liter replacement calibration gas - 20 ppm CO (USA)
Fits All models Part No.: BBG-20103
○ 17 liter replacement calibration gas - 10 ppm CO (Canada)
Fits All models Part No.: BBG-10017
○ 103 liter replacement calibration gas - 10 ppm CO (Canada)
Fits All models Part No.: BBG-10103
○ OSHA Grade D air sample test
Fits All models Part No.: BA-AST-GRD01
• Replacement Filter Elements
○ 0.01 micron coalescing pre filter elements
Fits BAP 050 CP Part No.: E 0050 M01
Fits BAP 100 CP Part No.: E 0135 M01
Fits BAP 175 CP Part No.: E 0175 M01
○ activated carbon filter elements
Fits BAP 050 CP Part No.: E 0050 AC
Fits BAP 100 CP Part No.: E 0135 AC
Fits BAP 175 CP Part No.: E 0175 AC
*Scroll to the right on mobile to see entire chart
Model |
Height (in) |
Width (in) |
Depth (in) |
Weight (lbs) |
BAP 050 CP N |
23" |
22" |
8.0" |
28 |
BAP 050 CP H |
23" |
22" |
8.0" |
28 |
BAP 050 CP S |
23" |
22" |
8.0" |
28 |
BAP 100 CP N |
23" |
22" |
8.0" |
40 |
BAP 100 CP H |
23" |
22" |
8.0" |
40 |
BAP 100 CP S |
23" |
22" |
8.0" |
40 |
BAP 175 CP N |
23" |
22" |
8.0" |
45 |
BAP 175 CP H |
23" |
22" |
8.0" |
45 |
BAP 175 CP S |
23" |
22" |
8.0" |
45 |